Product catalog
- HM10 High - accuracy Pressure Sensor
- HM20 General - type Pressure Transducer Description
- HM22 High - accuracy Pressure Transducer
- HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
- HM23Y Special Pressure Transducer for Oilfield and Mining Well
- HM24 Economical Pressure Sensor and Transducer
- HM25 Industrial - type Pressure Transducer
- HM26 Ceramic Capacitor Pressure Transducer
- HM27 Vacuum / Absolute Pressure Transducer
- HM28 Sapphire Pressure Transducer
- HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
- HM50 Anti - corrosive Pressure Transducer
- HM60 Anti - explosive Pressure Transducer
- HM70 Hygienic Flat - membrane Pressure Transducer
- HM80 High - temperature Pressure Transducer
- HM90 High - frequency Dynamic Pressure Transducer
- HM91 Micro Pressure Sensor and Transducer
Contact Us
南京宏沐科技有限公司
銷售部地址:南京市高鐵南站南廣場
電話:400-063-9658
手機(jī):18951963348同微信號(hào)
傳真:025-52150140
郵箱:njhongmu@hmsensor.com
HM26 Ceramic Capacitor Pressure Transducer
Description
HM26 ceramic capacitor pressure transducer adopts internationally advanced ceramic capacitor sensor, supported with high–accuracy electronic elements, and assembling with strict process. It adopts dry pressure measuring technology without intermediate liquid, thick membrane electronic technology, SMT (surface mount technology) and PFM signal transferring technology to fully play a role of technical advantages for ceramic capacitor sensor so as to make that the pressure transducer features excellent technical performance. It features strong anti–overloading and anti–impact capacity, high stability, and very high accuracy of measurement. This series of product may widely be used for such industrial fields as petroleum, chemical, metallurgical, electric power, pharmaceutical, and food etc.
Features of Product
☆ Strong anti – overloading and anti – impact capacity, with over pressure up to several dozens to hundred times of scale
☆ Adoption of imported ceramic capacitor sensor, with strong signal output, high comprehensive accuracy, and good stability
☆Small temperature drifting due to without intermediate liquid for measuring element
☆ Wide range of pressure, from micro pressure 0.5kPa to high pressure 100MPa, with optional combined pressure with positive and negative pressure
☆ Pure ceramic substrate will not result process pollution. It applies to food and medical industrial.
☆ Strong disturbance immunity, water – proof, dust – proof, vibration – proof, explosion – proof, and corrosion – proof.
☆ Intrinsically safe explosion – proof, with explosion – proof Class Ex ia II CT5
Application of Product
Details
Measuring range | -100KPa ~ 0 ~ 5KPA…100MPa | |||
Overloading capacity | 3 ~ 100 times of maximum rated pressure (the smaller scale, the bigger over pressure times | |||
Type of pressure | Gauge pressure, absolute pressure | |||
Medium to be measured | Corrosive liquid, gas, and vapor (the medium compatible with AL2O3 and 1Cr18Ni9N) | |||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS | |
Medium temperature | -40~+125℃ |
| ||
Ambient temperature | -40~+85℃ |
| ||
Compensating temperature | -20~+80℃ |
| ||
Long – term stability | ± 0.1% FS / year | |||
Zero point temperature drifting | ± 0.02% FS / ℃ | |||
Sensitivity temperature drifting | ± 0.02% FS / ℃ | |||
Range of power supplying | 12 ~ 36V DC ( generally 24V DC) | |||
Signal output | 4~20mA / 1-5V DC / 0~5V DC | |||
Load resistance | ≤(U - 12) / 0.02Ω | |||
Material of structure | Membrane: AL2O3 ceramic | Enclosure: Cast aluminum with low copper content | ||
Connecting material: 1Cr18Ni9N | Sealing structure: NBR, PTFE or Fluorubber | |||
Safe explosion – proof | Ex ia II CT5 | |||
Enclosure protection degree | Plug type (IP65); cable type (IP67) | |||
Response time (10% ~ 90%) | ≤1ms | |||
Weight | Approx. 500g | |||
Thermal lagging | ± 0.01% FS (typical) | |||
Tolerance of vibration | ≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g) |
Product selection
HM26 | Ceramic Capacitor Pressure Transducer |
| Guideline of Selection | Ceramic Capacitor Pressure Transducer | ||||||||||
| Type of pressure | Gauge pressure (G, may not be indicated); absolute pressure (A), combined pressure with positive and negative pressure (F) | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output (Standard power supply of energization | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| B1 | Stainless steel structure | ||||
|
|
|
|
|
|
|
|
| B2 | PMP 133 aluminum alloy structure ( E + H) | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM26 G( 0 ~ 10KPa) |
| — 1 | — A1 | — F1 | — B1 -E Ceramic Capacitor Pressure Transducer |
Tips of Selection
- The medium to be measured shall be compatible with the material contacting with the product.
- The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
- Please contact us in case of the other special requirements and clearly indicate them when placing an order.