HM27 Vacuum / Absolute Pressure Transducer

Description

HM27 series of vacuum / absolute pressure transducer is a new series of product specially used for vacuum measuring control released in China by German HELM, which fully has solved the problem of difficult vacuum measurement. This series of product has three variants i.e. HM27G negative pressure transducer, HM27A absolute pressure transducer, HM27CA capacitor thin – membrane absolute pressure transducer, which has widely been used for such fields as pharmaceutical, medical equipment, airspace and aerospace, scientific research, leakage detection, accessories of automation equipment. HM27G negative pressure transducer adopts HELM mono – crystalline silicon thick – membrane sensor, provided with high – accuracy signal processing circuit, with performance stability and reliability, which has solved such disadvantages of domestic diffused silicon – type negative vacuum product as unstable signal and short service life. The normal ranges are 0 ~ 100KPa and 0 ~ 50KPa etc.

Features of Product

☆ Fully provided with German HELL made high – accuracy sensing elements, with maximum accuracy up to 0.1% FS 

☆ Stable and reliable performance, may be continuously operated for a long time, with good long – term stability 

☆ May apply to measure corrosive medium under special requirements 

☆ Strong overloading immunity ☆ Fast response 

☆ May be used for hazardous site, with intrinsically safe type Ex ia II CT5 

☆ Structural diversification, design may be customized at the customer’s special requirements.

Application of Product

Details

HM27A negative pressure transducer adopts    such new high technologies of German HELM as advanced absolute pressure chip,    temperature automatic compensation, and normalized circuit commissioning etc.    to expand the absolute pressure range to 5KPa, as a minimal, and to greatly    enhance the overall accuracy of the product. This variant features advanced    technology, superior performance, reliable quality, small dimensions. It    features more advantages and high ratio of performance to cost comparing with    the same type of domestic absolute pressure product.
           HM27CA    capacitor thin – membrane absolute pressure transducer is a vacuum pressure    gauge made in China    through introduction of capacitor thin – membrane from German HELM and    internationally advanced calibration and production equipment. This product    adopts the capacitor capacity changing principle to work, of which minimum    scale may be up to 0.02MPa ~ 200MPa of absolute pressure, without influenced    by the category and composite of the medium to be detected when detecting, with    output of standard electrical signal, may be remote transferring, easily    intellectual control by micro – processor. It is ideal for measurement of low    vacuum pressure.

Technical  Data


           Medium to be measured

The gas or liquid, and    compatible with 316 stainless steel

Type of pressure

Negative gauge    pressure (G),  silicon – type absolute    pressure (A), capacitor thin – membrane absolute pressure (CA)

Overloading capacity

Two times for negative    gauge pressure, several dozens to several hundred times for micro - scale absolute    pressure

Measuring range

Negative gauge    pressure: 0 ~ 5KPa…-_50KPa…-100Kpa
           Silicon – type    absolute pressure: 0 ~ 5KPa…10KPa…20KPa0 ~ 100KPa…200KPa…1Mpa
           Capacitor thin –    membrane absolute pressure: 0.02Pa ~ 200Pa. 1Pa ~ 1KPa

Overall accuracy
           Non - linear, repeatability,    lagging

 ± 0.1% FS

 ± 0.25% FS

 ± 0.5% FS

Long – term stability

Typical:  ± 0.1% FS / year

Maximum:  ± 0.1% FS / year

Range of operating    temperature

-20~+80℃

Range of Compensating temperature

-10~+80℃

 

Ambient temperature

-20~+80℃

 

Zero point temperature    drifting

Typical:  ± 0.01% FS / ℃

Typical:  ± 0.15% FS / ℃

Sensitivity    temperature drifting

Typical:  ± 0.01% FS / ℃

Typical:  ± 0.15% FS / ℃

Range of power    supplying

12 ~ 36V DC (    generally 24V DC)

Signal output

4~20mA / 1-5V DC / 0~5V DC

Load resistance

≤(U - 12) / 0.02Ω

Enclosure protection    degree

Plug type (IP65);    cable type (IP67)

Safe explosion – proof

Ex ia II CT5

Tolerance of vibration

≤ ± 0.01% FS(Axles X, Y,    and Z, 200Hz / g)

Resolution

Infinite small    (theoretical), 1 / 100000 (general)

Response time (10% ~ 90%)

≤1ms

Product selection

HM27

Vacuum / Absolute Pressure Transducer

 

Guideline of Selection

Vacuum / Absolute    Pressure Transducer

 

Type of pressure

Gauge pressure (G, may not be indicated); absolute pressure (A), capacitor    thin – membrane absolute pressure (CA)

 

 

Range

Measuring Range

 

 

0 ~ X KPa or 0 ~ X MPa

 

 

 

 

 

Code

Overall accuracy (linear + repeatability + lagging)

 

 

 

 

 

1

 ± 0.5% FS

 

 

 

 

 

2

 ± 0.25% FS

 

 

 

 

 

3

 ± 0.1% FS

 

 

 

 

 

 

 

Code

Signal Output (Standard power supply of energization

 

 

 

 

 

 

 

A1

4 ~ 20mA (12 ~ 36V DC)

 

 

 

 

 

 

 

V1

1 ~ 5V DC (12 ~ 36V DC)

 

 

 

 

 

 

 

V2

0 ~ 5V DC (12 ~ 36V DC)

 

 

 

 

 

 

 

V3

0.5 ~ 4.5V DC (12 ~ 36V DC)

 

 

 

 

 

 

 

 

 

Code 

Additional functions

 

 

 

 

 

 

 

 

 

F1

M20 x 1.5 external thread

 

 

 

 

 

 

 

 

 

F2

G 1 / 4 external thread

 

 

 

 

 

 

 

 

 

F3

Clamped type

 

 

 

 

 

 

 

 

 

F0

Special

 

 

 

 

 

 

 

 

 

W1

Cable type (IP67, 2m)

 

 

 

 

 

 

 

 

 

W2

Socket type (IP65, DIN 43650)

 

 

 

 

 

 

 

 

 

W3

Airspace and aerospace plug

 

 

 

 

 

 

 

 

 

P

Flushed membrane type

 

 

 

 

 

 

 

 

 

E

Intrinsically safe explosion - proof type Ex ia II CT5

 

 

 

 

 

 

 

 

 

 

 

 

HM27   A( 0 ~ 10KPa)

 

— 1

— A1

— F1

— W2 Vacuum / Absolute Pressure Transducer


Tips of Selection

  1. The medium to be measured shall be compatible with the material contacting with the product.
  2. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
  3. Please contact us in case of the other special requirements and clearly indicate them when placing an order.


bottom-nav_01.png

主要產(chǎn)品:
HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |