Product catalog
- HM10 High - accuracy Pressure Sensor
- HM20 General - type Pressure Transducer Description
- HM22 High - accuracy Pressure Transducer
- HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
- HM23Y Special Pressure Transducer for Oilfield and Mining Well
- HM24 Economical Pressure Sensor and Transducer
- HM25 Industrial - type Pressure Transducer
- HM26 Ceramic Capacitor Pressure Transducer
- HM27 Vacuum / Absolute Pressure Transducer
- HM28 Sapphire Pressure Transducer
- HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
- HM50 Anti - corrosive Pressure Transducer
- HM60 Anti - explosive Pressure Transducer
- HM70 Hygienic Flat - membrane Pressure Transducer
- HM80 High - temperature Pressure Transducer
- HM90 High - frequency Dynamic Pressure Transducer
- HM91 Micro Pressure Sensor and Transducer
Contact Us
南京宏沐科技有限公司
銷售部地址:南京市高鐵南站南廣場
電話:400-063-9658
手機:18951963348同微信號
傳真:025-52150140
郵箱:njhongmu@hmsensor.com
HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
Description
HM29 digital ? intellectual pressure / differential pressure transducer is a high – accuracy digital and intellectual product developed by German HELM to meet the market needs of Chinese mainland. This series of product adopt German HELM made sensor chip with highest performance and are designed incorporating with monolithic computer technology and sensor digital conversion technology, of which core component adopts 24–bit AD MCU micro – processor to ensure high quality of the transducer relying on its strong function and high – speed operation capacity. The overall designed framework is to meet the requirements of increasingly enhanced industrial site application with a view to reliability, stability, high accuracy, and intellectualization. Meanwhile, the supporting software of the product also features strong function and without manually operating device to ensure good interaction. Application digital signal processing technology is made for good disturbance immunity. It also features zero point automatic stable follow – up capacity and temperature automatic compensation capacity.
Features of Product
☆ Baud rate from 1200 to 230400 bps
☆Overall accuracy up to ± 0.05% FS under special condition
☆ Optional many kinds of pressure unit, may be user – defined
☆ Sampling rate form 10 points / second to 1 point / 50 minutes
☆ RS 485 universal serial bus (USB) loop may connected with 63 sensor, as a maximal
☆ Communication with the computer via control software in Chinese as well as USB, RS - 232 / 485 port, with easy operation☆ Provided with micro – processor for digital compensation, control, and communication
☆ USB, RS - 232 / 485 port directly connecting with the computer
Application of Product
☆ 20 – bit effective resolution
☆ Absolute pressure, gauge pressure, and differential pressure
☆ Zero point and FS output setting
☆ Readable temperature value of the medium to be measured
Details
☆ National defense scientific research | ☆ Scientific research and laboratory calibration |
☆ Nuclear power generation and chemical | ☆ Petroleum survey and investigation |
☆ Military | ☆ High – end equipment accessories |
☆ Airspace and aerospace | ☆ Support for engineering projects |
Technical Data | ||||
Measuring range | -100kPa ~ 0 ~ 5KPa … 100MPa | |||
Overloading capacity | Two times of FS pressure (where over pressure for 100MPa is designed with 1.1 times of FS pressure) | |||
Pressure type | Gauge pressure or absolute pressure | |||
Medium to be measured | The gas or liquid compatible with 316 stainless steel | |||
Overall accuracy | ± 0.05% FS | ± 0.075% FS | ± 0.1% FS | ± 0.25% FS |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year | ||
Zero point temperature drifting | Typical: ± 0.005% FS | Maximum: ± 0.01% FS / ℃ | ||
Sensitivity temperature drifting | Typical: ± 0.005% FS | Maximum: ± 0.01% FS / ℃ | ||
Range of operating temperature | -40 ~ +85 ℃ | |||
Range of compensating temperature | -10 ~ +60 ℃ | |||
Range of power supplying | 5 ~ 9V DC | |||
Digital output | RS485 / USB / RS232 | |||
Baud rate | 1200 , 2400 , 9600 , 19200 , 28800 , 57600 , 115200 , 230400 | |||
Data format | 1–bit start bit, 8–bit data bit, 1–bit stop bit | |||
Odd and even calibration | None | |||
Sampling rate | 10 points / second – 1 point / 50 minutes | |||
Resolution | 20 bit 10ppm |
Product selection
HM28 | Digital · Intellectual Pressure / Differential Pressure Transducer |
| Guideline of Selection | Digital · Intellectual Pressure / Differential Pressure Transducer | ||||||||||
| Code | Type of pressure | ||||||||||||
| G | Gauge pressure ( may not be indicated) | ||||||||||||
| A | Absolute pressure | ||||||||||||
| D | Differential | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.25% FS | ||||||||
|
|
|
|
| 2 | ± 0.1% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
| 4 | ± 0.075% FS | ||||||||
|
|
|
|
| 3 | ± 0.05% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output Method | ||||||
|
|
|
|
|
|
| S1 | RS 458 | ||||||
|
|
|
|
|
|
| S2 | RS 232 | ||||||
|
|
|
|
|
|
| S3 | USB | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM29 9( 0 ~ 100KPa) |
| — 4 | — S1 | — F1 | — W1 Digital · Intellectual Pressure / Differential Pressure Transducer |
Tips of Selection
- The medium to be measured shall be compatible with the material contacting with the product.
- The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
- Please contact us in case of the other special requirements and clearly indicate them when placing an order.