Product catalog
- HM10 High - accuracy Pressure Sensor
- HM20 General - type Pressure Transducer Description
- HM22 High - accuracy Pressure Transducer
- HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
- HM23Y Special Pressure Transducer for Oilfield and Mining Well
- HM24 Economical Pressure Sensor and Transducer
- HM25 Industrial - type Pressure Transducer
- HM26 Ceramic Capacitor Pressure Transducer
- HM27 Vacuum / Absolute Pressure Transducer
- HM28 Sapphire Pressure Transducer
- HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
- HM50 Anti - corrosive Pressure Transducer
- HM60 Anti - explosive Pressure Transducer
- HM70 Hygienic Flat - membrane Pressure Transducer
- HM80 High - temperature Pressure Transducer
- HM90 High - frequency Dynamic Pressure Transducer
- HM91 Micro Pressure Sensor and Transducer
Contact Us
南京宏沐科技有限公司
銷售部地址:南京市高鐵南站南廣場
電話:400-063-9658
手機:18951963348同微信號
傳真:025-52150140
郵箱:njhongmu@hmsensor.com
HM80 High - temperature Pressure Transducer
Description
For general pressure – resistance type pressure sensor, the four force – sensitive resistors of sensitive Wheatstone bridge for control and measuring are manufactured in IC technology, between the resistors is isolated with PN junction each other. The highest operating temperature is only 125℃ due to temperature resistant limitation of the PN junction. However, the performance of sensor has greatly been deteriorated after the temperature is above 100℃ because reverse current leakage of the PN junction rises with the exponent of the temperature. Utilization of multi-crystalline silicon SOI technology to make force – sensitive resistor may expand the operating temperature up to 150℃. Utilization traditional SOS technology and advance SOI technology may expand the operating temperature up to 150℃ ~ 350℃. Utilization of state – of – the – art β–phase high – temperature force - sensitive material, i.e. SiC, incorporating with SOI technology may expand the operating temperature up to 450℃ ~ 850℃. This series of product adopts German HELM made internationally advanced sensor, provided with high – accuracy electronic elements through strict assembling process.
Features of Product
☆ Provided with enclosure fully made of stainless steel, with excellent corrosion resistant performance
☆Wide range of pressure measurement
☆Wide range of temperature measurement, with very small tolerance of temperature
☆ Working stability and strong disturbance immunity
☆ High reliability and with dual – membrane structure
☆ Small dimensions, light weight, and full variants
☆ Reverse - phase pole over – voltage and over – current protection
☆ Wide range of measuring medium
Application of Product
☆ Industrial process control
☆ Chemical
☆ Power generation engineering
☆ Thermal energy engineering
☆ Petroleum survey and investigation
☆ Airspace and aerospace
☆ Scientific research of national defense
Details
Technical Data | HM80 High - temperature Pressure Transducer | ||||
Measuring range | 0 ~ 10KPa … 1MPa … 100MPa | ||||
Overloading capacity | Two times of FS pressure ((where over pressure for 100MPa is designed with 1.1 times of FS pressure) | ||||
Pressure type | Gauge pressure or absolute pressure or sealed reference pressure | ||||
Medium to be measured | The liquid, gas or vapor compatible with 316 stainless steel | ||||
Overall accuracy | ± 0.25% FS | ± 0.5% FS | ± 1% FS | ||
Operating temperature zone | -40℃ ~ +150℃ | -40℃ ~ +200℃ | -55℃ ~ +250℃ | -25℃ ~ +350℃ | |
Compensating temperature zone | -20℃ ~ +130℃ | -20℃ ~ +180℃ | -20℃ ~ +200℃ | 0℃ ~ +250℃ | |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.02% FS / year | |||
Zero point temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |||
Sensitivity temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | ||||
Signal output | 4 ~ 20mA / 1 ~ 5V DC / 0 ~ 5V DC | ||||
Load resistance | ≤ (U-12) / 0.02Ω | ||||
Response time | ≤3 ms | ||||
Thermal lagging | ± 0.1% (typical) | ||||
Tolerance of vibration | ≤ ± 0.01% FS ( Axles X, Y , Z, 200Hz / g ) | ||||
Insulation resistance | 100MΩ 500V DC | ||||
Safe explosion – proof | Ex ia II CT5 | ||||
Enclosure protective degree | Plug type (IP 65); Cable type (IP 67) |
Product selection
HM80 | High - temperature Pressure Transducer |
| Guideline of Selection | ||||||||||
| Type of pressure | Gauge pressure ( G, may not be indicated), Absolute pressure (A) | |||||||||||
|
| Range | Measuring Range | ||||||||||
|
| (0 ~ X KPa or 0 ~ X MPa | |||||||||||
|
|
| Code | Range of operating temperature | |||||||||
|
|
| C1 | — 40℃ ~ + 150℃ | |||||||||
|
|
| C2 | — 40℃ ~ + 200℃ | |||||||||
|
|
| C3 | — 55℃ ~ + 250℃ | |||||||||
|
|
| C4 | — 25℃ ~ + 350℃ | |||||||||
|
|
| C5 | 0℃ ~ + 800℃0( High - temperature, water - cooled) | |||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | |||||||
|
|
|
|
| 0 | ± 1.0% FS | |||||||
|
|
|
|
| 1 | ± 0.5% FS | |||||||
|
|
|
|
| 2 | ± 0.25% FS | |||||||
|
|
|
|
|
|
| Code | Signal Output (Standard power supply of energization) | |||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA ( 12 ~ 36V DC) | |||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC ( 12 ~ 36V DC) | |||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC ( 12 ~ 36V DC) | |||||
|
|
|
|
|
|
|
|
| Code | Additional functions | |||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | |||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | |||
|
|
|
|
|
|
|
|
| F0 | Special | |||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | |||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | |||
|
|
|
|
|
|
|
|
| P | Flushed membrane | |||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
HM80 ( 0 ~ 10MPa) | — C1 | — 1 | — A1 | — F1 | — W1 High - temperature Pressure Transducer |
Tips of Selection
- The medium to be measured shall be compatible with the material contacting with the product.
- The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
- Please contact us in case of the other special requirements and clearly indicate them when placing an order.