Product catalog
- HM10 High - accuracy Pressure Sensor
- HM20 General - type Pressure Transducer Description
- HM22 High - accuracy Pressure Transducer
- HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
- HM23Y Special Pressure Transducer for Oilfield and Mining Well
- HM24 Economical Pressure Sensor and Transducer
- HM25 Industrial - type Pressure Transducer
- HM26 Ceramic Capacitor Pressure Transducer
- HM27 Vacuum / Absolute Pressure Transducer
- HM28 Sapphire Pressure Transducer
- HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
- HM50 Anti - corrosive Pressure Transducer
- HM60 Anti - explosive Pressure Transducer
- HM70 Hygienic Flat - membrane Pressure Transducer
- HM80 High - temperature Pressure Transducer
- HM90 High - frequency Dynamic Pressure Transducer
- HM91 Micro Pressure Sensor and Transducer
Contact Us
南京宏沐科技有限公司
銷售部地址:南京市高鐵南站南廣場(chǎng)
電話:400-063-9658
手機(jī):18951963348同微信號(hào)
傳真:025-52150140
郵箱:njhongmu@hmsensor.com
HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
Description
HM23 series of pressure transducer is specially designed for accurate measurement of pressure in air conditioner, refrigerating and compressor as well as hydraulic system, including multiple refrigerants, mixture of refrigerant and lubricant, oil, water, gas etc. It is designed and manufactured in ODM way. Our design team may improve or re-design to meet the requirements of the individual customer at the customer’s requests.
Features of Product
☆ Designed with a built - in stabilizer, may use any unadjusted power supply of energization under a certain range.
☆ Designed with Solid structure and effective moisture – proof protection to ensure that the sensor may be installed and operated in very bad environment.
☆ Designed with wide – range temperature compensation to effectively reduce the influence of ambient temperature and the temperature of medium measured to the transducer.
☆ Excellent long-term stability
☆ Designed with Electromagnetic compatibility (EMC) protection to meet the relevant requirements of IEC.
Application of Product
Details
Measuring range | 0~100KPa…60MPa | |
Overloading capacity | Two times of full–scale pressure | |
Type of pressure | Gauge pressure or absolute pressure | |
Medium to be measured | The gas or liquid compatible with 316 stainless steel , | |
Overall accuracy | Typical: ± 0.25% FS | Maximum: ± 0.4% FS |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year |
Zero point temperature drifting | Typical: ± 0.015% FS / ℃ | Maximum: ± 0.03% FS / ℃ |
Sensitivity temperature drifting | Typical: ± 0.015% FS / ℃ | Maximum: ± 0.03% FS / ℃ |
Response time | ≤3ms | |
Medium temperature | -40~125℃ | |
Compensating temperature | -20~80℃ | |
Ambient temperature | -40~75℃ | |
EMC - radioactivity | EN50081-1 | |
Static discharging disturbance immunity | Air: 8KV; Contact: 4KV (IEC61000-4-2:1995) | |
RF electromagnetic field radiation disturbance immunity | 10V / M 80-1000MHz (IEC61000-4-3:1995) | |
RF electromagnetic field conduction disturbance immunity | 3emf / V150K-80MHz (IEC61000-4-6:1996) | |
Electrically quick transient pulse group disturbance immunity | 2KV 5KHz (IEC61000-4-4:1995) | |
Tolerance of vibration | ≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g) | |
Surge disturbance immunity | 2KV (IEC61000-4-6:1996) | |
Insulation resistance | >100 MΩ, 100V DC | |
Main frequency test | 500V 50Hz SEN361503 | |
Vibrating stability | Random 10G 10-2000Hz, Sine 25G | |
Protection degree | Plug type IP65-IEC60529, cable type IP67-IEC60529 | |
Intrinsically safe explosion – proof | Ex ia II CT5 | |
Thermal lagging | ± 0.1% FS | |
Load resistance | ≤(U-12) / 0.02Ω | |
Weight | Approx. 250g |
Product selection
HM23 | Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor |
| Guideline of Selection | Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor | ||||||||||
| Type of pressure | Gauge pressure (G, may not be indicated); absolute pressure (A) | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X KPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | ||||||
|
|
|
|
|
|
|
|
| Code |
| Additional functions | |||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F4 | 1 / 2 - 20 UNF -2A | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | φ26 Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | φ26 Socket type (IP65, DIN43650) | ||||
|
|
|
|
|
|
|
|
| W3 | φ38 Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W4 | φ38 Socket type (IP65, DIN43650) | ||||
|
|
|
|
|
|
|
|
| W5 | φ35 Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W6 | φ38 Socket type (IP65, DIN43650) | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM23 ( 0 ~ 1.6MKPa) |
| — 1 | — A1 | — F1 | — W2 Special Pressure Transducer for Air Conditioner, |
Tips of Selection
- The medium to be measured shall be compatible with the material contacting with the product.
- The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
- Please contact us in case of the other special requirements and clearly indicate them when placing an order.