Product catalog
- HM10 High - accuracy Pressure Sensor
- HM20 General - type Pressure Transducer Description
- HM22 High - accuracy Pressure Transducer
- HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
- HM23Y Special Pressure Transducer for Oilfield and Mining Well
- HM24 Economical Pressure Sensor and Transducer
- HM25 Industrial - type Pressure Transducer
- HM26 Ceramic Capacitor Pressure Transducer
- HM27 Vacuum / Absolute Pressure Transducer
- HM28 Sapphire Pressure Transducer
- HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
- HM50 Anti - corrosive Pressure Transducer
- HM60 Anti - explosive Pressure Transducer
- HM70 Hygienic Flat - membrane Pressure Transducer
- HM80 High - temperature Pressure Transducer
- HM90 High - frequency Dynamic Pressure Transducer
- HM91 Micro Pressure Sensor and Transducer
Contact Us
南京宏沐科技有限公司
銷售部地址:南京市高鐵南站南廣場
電話:400-063-9658
手機(jī):18951963348同微信號
傳真:025-52150140
郵箱:njhongmu@hmsensor.com
HM30 Micro Differential Pressure / Air Pressure Transducer
Description
HM10 High - accuracy piezoresistive pressure sensor is encapsulated in stainless steel case through assembly and commissioning adopting advanced silicon piezoresistive sensitive elements made by German HELM Company. Both the case and the port are made of stainless steel. The medium are of good compatibility, with stable and reliable performance, and high accuracy. The gasket is applied on the end face.
Features of Product
☆ High ratio of performance to ratio
☆ From 0 ~ 0.5KPa to 0 ~ 700KPa
☆ Continuously adjustable zero point and full scale☆ Reverse pole protection and current limit protection
☆ Lightning, radio frequency immunity
☆ Compact structure, beautiful appearance, and easy installation
☆ Normalized design and production to ensure stable quality and performance of the product
☆ May be designed or improved as per the customer’s specific requirements
Application of Product
☆ Measurement of air pressure and flow rate in industrial process
☆ HVAC
☆ Hearth pressure or hearth negative pressure
☆ Monitoring in – the – well ventilation
☆ Purification equipment and cleaning engineering
☆ Flue dust control and protection of environment
☆ Drying chamber pressure boosting and furnace ventilation control
☆ Medial instrument and equipment
☆ Air fan measurement and control
Details
Technical Data | |||
Measuring range | Differential pressure / air pressure : 0 ~ 500Pa…700KPa | ||
Negative pressure: 0 ~ -500Pa…-1KPa…-10KPa…-100KPa | |||
Permissible over pressure | Three times of FS pressure | ||
Medium to be measured | Non – corrosive, dust and powder free, and dry fluid | ||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS |
Medium temperature | -20 ~ +85 ℃ | ||
Compensating temperature | -10 ~ +55 ℃ | ||
Ambient temperature | -10 ~ +80 ℃ | ||
Zero point temperature drifting | Typical: ± 0.2% FS | Maximum: ± 0.05% FS / ℃ | |
Sensitivity temperature drifting | Typical: ± 0.2% FS | Maximum: ± 0.05% FS / ℃ | |
Long – term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year | |
Range of power supplying | 12 ~ 36V DC (24V DC generally) | ||
Signal output | 4 ~ 20mA / 1 ~ 5V DC | ||
Load resistance | ≤ (U-12) / 0.02Ω | ||
Enclosure material | Hard aluminum alloy surface plastic injection or 304 stainless steel | ||
Protection degree | IP 65 or IP 67 | ||
Process Connection | φ8 tip, with M10×1 installing screws | ||
Explosion – proof marking | Ex ia II CT5 (intrinsically safe explosion – proof) | ||
Weight | Approx. 0.35kg | ||
Response time | ≤1 ms | ||
Thermal lagging | ± 0.01% FS (typical) | ||
Vibrating tolerance | ≤ ± 0.01% FS ( Axles X, Y , Z, 200Hz / g ) | ||
Insulation resistance | 100MΩ, 500V DC | ||
Resolution | Infinite small (theoretical) 1 / 100000 (general) |
Product selection
HM30 | Micro Differential Pressure / Air Pressure Transducer |
| Guideline of Selection | Micro Differential Pressure / Air Pressure Transducer | ||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F3 | φ8 tip, with M10×1 installing screws | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| W3 | Aerospace socket type (IP65) | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM30 (0 ~ 500MPa) |
| — 1 | — A1 | — F2 | — W1 Micro Differential Pressure / Air Pressure Transducer |
Tips of Selection
The medium to be measured shall be compatible with the material contacting with the product. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier. Please contact us in case of the other special requirements and clearly indicate them when placing an order.