Product catalog
- HM10 High - accuracy Pressure Sensor
- HM20 General - type Pressure Transducer Description
- HM22 High - accuracy Pressure Transducer
- HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
- HM23Y Special Pressure Transducer for Oilfield and Mining Well
- HM24 Economical Pressure Sensor and Transducer
- HM25 Industrial - type Pressure Transducer
- HM26 Ceramic Capacitor Pressure Transducer
- HM27 Vacuum / Absolute Pressure Transducer
- HM28 Sapphire Pressure Transducer
- HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
- HM50 Anti - corrosive Pressure Transducer
- HM60 Anti - explosive Pressure Transducer
- HM70 Hygienic Flat - membrane Pressure Transducer
- HM80 High - temperature Pressure Transducer
- HM90 High - frequency Dynamic Pressure Transducer
- HM91 Micro Pressure Sensor and Transducer
Contact Us
南京宏沐科技有限公司
銷(xiāo)售部地址:南京市高鐵南站南廣場(chǎng)
電話:400-063-9658
手機(jī):18951963348同微信號(hào)
傳真:025-52150140
郵箱:njhongmu@hmsensor.com
HM31 Differential Pressure Transducer
Description
HM31 differential pressure transducer adopts German HELM made differential pressure sensitive chip and special transducer integrated circuit as well as high – performance key set and strict production process to ensure that this series of product features superior performance, small dimensions, easy installation, which is best ideal for measurement of micro differential pressure, flow field, flow rate, and flow.
Features of Product
☆High ratio of performance to cost
☆ Fully made of stainless steel with small dimensions, light weight, and easy installation
☆ Reliable and stable performance
☆ Range of differential pressure: 0 ~ 10KPa … 2MPa
☆ Static high pressure resistant to 20MPa
Application of Product
☆ Industrial process control
☆ Flow measurement
☆ Medical instrument
☆ Air power measurement
☆ Hydraulic and pneumatic equipment
Details
| ||||||||||
Measuring range | 0 ~ 10KPa…2MPa | |||||||||
Full scale range | 10 ~ 50KPa | 50 ~ 100KPa | 0.1 ~ 0.2MPa | 0.2 ~ 0.5MPa | 0.5 ~ 1MPa | 1 ~ 2MPa | ||||
Positive permissible over pressure | 250KPa | 300KPa | 0.4MPa | 1.0MPa | 2MPa | 4MPa | ||||
Negative permissible over pressure | 100KPa | 200KPa | 0.3MPa | 0.5MPa | 0.7MPa | 1MPa | ||||
Maximun static pressure | ≤20Mpa | |||||||||
Overall accuracy | ± 0.1%FS | ± 0.25%FS | ± 0.4%FS | |||||||
Zero point temperature drifting | ± 0.02%FS / ℃ (typical) | ± 0.05%FS / ℃ (maximum) | ||||||||
Sensitivity temperature drifting | ± 0.02%FS / ℃ (typical) | ± 0.05%FS / ℃ (maximum) | ||||||||
Influence of static pressure | ± 0.05%FS / 100KPa | |||||||||
Range of operating temperature | -10℃ ~ 80℃ | |||||||||
Range of compensating temperature | -10℃ ~ 50℃ | |||||||||
Long-term stability | ± 0.3%FS / year (≤200KPa) | ± 0.1%FS / year (≥200KPa) | ||||||||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | |||||||||
Signal output | 2-wire 4~20mA; s-wire 0 / 1-5V DC | |||||||||
Response time | ≤2ms | |||||||||
Insulation resistance | 100MΩ, 500V DC | |||||||||
Influence of vibration | Change ≤1% after vibration of 3gRMS30 ~ 2000Hz | |||||||||
Impact | Change ≤1% after impact of 100g for 10ms | |||||||||
Service life | 1×108 pressurized cycle | |||||||||
Medium | The gas or liquid compatible with material of structure | |||||||||
Explosion – proof marking | Ex ia II CT5 (intrinsically safe explosion – proof | |||||||||
Weight | Approx 0.35KG | |||||||||
Thermal lagging | ± 0.1%FS (typical) | |||||||||
Enclosure protective degree | Plug Type (IP 65) | Cable Type (IP 67) |
Product selection
HM31 | Differential Pressure Transducer |
| Guideline of Selection | Differential Pressure Transducer | ||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output (standard power supply of energization) | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM31 (0 ~ 50kPa) |
| — 1 | — A1 | — F2 | — W1 Differential Pressure Transducer |
Tips of Selection
It is recommended that three – valve set should be installed between the point to be measured and the transducer to make sure the medium to be measured is slowly and evenly applied on the positive and negative chambers in order to ensure running safety and reliability of the transducer. It is recommended that the pressure ports on both ends should be located above the horizontal line so as to minimize the influence of the installing position to the product when installing. Please pay attention to the static pressure to be measured shall be less than 20MPa and the over pressure applied on the positive and negative chamber shall not exceed the specified value of the product when selecting. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier. Please contact us in case of the other special requirements and clearly indicate them when placing an order.