国产精品毛片一区二区网_精品成人久久三级日韩麻豆_亚洲欧美国产日韩在线高清无广告_日韩美女护士性爱视频_乱伦亚洲精品无码_外围国产理论片_四虎成人免费电影_欧美日韩午夜视频在线观看_免费女同在线一区二区三区_我日亚洲av电影久久久

Click Close


阿里巴巴品牌店


天貓旗艦店

631349229

400-063-9658

cccc.jpg

TOP

中文ENGLISH
Location: Home>Products Introduction>Liquid

HM21F Lightning Liquid Level Transducer

Description

HM21F lightning liquid level transducer measures the liquid level using the principle that the liquid static pressure is directly proportion to the liquid height. This series of product is specially designed for the thundering areas in the Southern China using advanced silicon piezoresistive sensitive element made by German HELM Company, supported with HELM–patent lightning device. It is suitable for hydrographic and water conservancy liquid level measurement in the river, lake, and reservoir. It has successfully been applied in many hydrographic industries.

Features of Product

☆ Simply installation, easy operation, strong interchangeability; 

☆ Power supplied from 12V battery under special condition to solve the problem of power supplying in the field. 

☆ Designed with lightning device and intrinsically safe explosion–proof capacity and may apply to all kinds of hazardous sites. 

☆ The high–quality sensor is designed with high sensitivity and fast response to accurately reflect tiny change of dynamic or static liquid level, with high accuracy of measurement. 

☆ Fine and unique zero point, temperature drifting, non–linear compensation to ensure good accuracy and long–term stability of the instruments and meters with the working condition.

Application of Product

(防雷液位變送器,防雷液位傳感器,防雷水位傳感器,防雷水位變送器,防雷水位計(jì)) 

適用于野外江、河、湖、水庫、高位水箱,尤其是南方強(qiáng)雷區(qū)以及北方高山地區(qū)水文水利的液位測(cè)量


Details

? ? ? Application of Product ? ? ?
It applies to river, lake, reservoir, and overhead  water tank, especially for hydrographic and water conservancy liquid level measurement  in the thundering areas in the Southern China and Mountainous area in the Northern China.

Measuring range

0 ~ 0.5m…200mH2O or 0    ~ 5KPa…2MPa

Permissible over    pressure

Two times of    full–scale pressure

Medium to be measured

The gas or liquid compatible    with 316 stainless steel,  corrosion–proof    type subject to special conditions

Overall accuracy
           (Linear, repeatability,    lagging)

 ± 0.25% FS 

 ± 0.4% FS

 ± 1% FS

Long-term stability

Typical:  ± 0.1% FS    

Maximum:  ± 0.2% FS

Range of operating    temperature

Integrated: - 20℃~70℃

Split: - 20℃~80℃

Range of compensating    temperature

Integrated: - 10℃~55℃

Split: - 10℃~70℃

Zero point temperature    drifting

Typical:  ± 0.02% FS / ℃

Typical:  ± 0.05% FS / ℃

Sensitivity temperature    drifting

Typical:  ± 0.02% FS / ℃

Typical:  ± 0.05% FS / ℃

Range of power    supplying

12 ~ 36V DC( generally    24V DC)

Signal output

4~20mA / 1 - 5V DC / 0~5V DC

Load resistance

≤(U - 12) / 0.02Ω

Material of structure 

Enclosure: Stainless    steel 1Cr18Ni9N

Membrane: Stainless    steel 316L

Sealing: Fluorubber

Cable: ¢7.2mm PVC, special

Insulation resistance

100MΩ, 500V DC

Protection degree

1P68

 

 

Thermal lagging

± 0.1% FS

Response time

≤2ms

Safe explosion - proof

Ex ia II CT5

Lightness degree

Class III lightning    design (10000V / 5000kA; ( Optional 20000V / 10000A) under special condition

Weight

Approx. 500g

? ? ? Features of Product ? ? ?
☆ Simply installation, easy operation, strong interchangeability;
☆ Power supplied from 12V battery under special condition to solve the  problem of power supplying in the field.
☆  Designed with lightning device and intrinsically safe explosion–proof capacity  and may apply to all kinds of hazardous sites.
☆  The high–quality sensor is designed with high sensitivity and fast response to  accurately reflect tiny change of dynamic or static liquid level, with high  accuracy of measurement.
☆  Fine and unique zero point, temperature drifting, non–linear compensation to  ensure good accuracy and long–term stability of the instruments and meters with  the working condition.

HM21F

Lightning Liquid Level Transducer

 

Guideline of Selection

 Lightning Liquid Level Transducer

 

Range

Measuring Range

 

0 ~ X mH2O or 0 ~ X KPa

 

 

 

Code

Structural form (maximum range of operating scale)

 

 

 

C1

Integrated: (0 ~ 200mH2O)

 

 

 

C2

Split: (0 ~ 10mH2O)

 

 

 

C3

Inserted: (0 ~ 4mH2O)

 

 

 

 

 

Code

Overall accuracy (linear + repeatability + lagging)

 

 

 

 

 

0

 ± 0.1% FS

 

 

 

 

 

1

 ± 0.4% FS

 

 

 

 

 

2

 ± 0.25% FS

 

 

 

 

 

 

 

Code

Signal Output (standard power supply of energization)

 

 

 

 

 

 

 

A1

4 ~ 20mA(12 ~ 36V DC)

 

 

 

 

 

 

 

V1

1 ~ 5V(12 ~ 36V DC)

 

 

 

 

 

 

 

V2

0 ~ 5V DC(12 ~ 36V DC)

 

 

 

 

 

 

 

 

 

Code 

Additional functions

 

 

 

 

 

 

 

 

 

F1

G 1 1 / 2 external thread (split and inserted)

 

 

 

 

 

 

 

 

 

F2

DN 20 flange (split and inserted)

 

 

 

 

 

 

 

 

 

F0

Special

 

 

 

 

 

 

 

 

 

E

Intrinsically safe explosion - proof type Ex ia II CT5

 

 

 

 

 

 

 

 

 

 

 

 

HM21F ( 0 ~ 10mH2O)

 —C 1

— 1

— A1

 

 

— E

 Lightning Liquid Level Transducer

Tips  of Selection

  1. The medium to be measured shall be compatible with the material  contacting with the product. Meanwhile, it is needed to be indicated with  density of the medium to be measured under the measuring status (except for  water).
  2. Please indicate when placing an order in case of battery power supplying.
  3. The F1, F2, and F0  shown as the additional functions are only suitable for split–type liquid level  transducer and inserted–type liquid level transducer.
  4. The code E, an additional functional code for selection, and  intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via  safety barrier.
  5. The length of cable shall be L = X m + 1m. Please indicate for extension when placing an  order. There are two kinds of cable material. The polyurethane is more flexible  with good wear resistance, which may be selectively used. Under the condition  without special indication, the PVC cables shall be supplied.
  6. The corresponding relationship of 1m water column under standard condition ( i.e. 4℃, g = 9.80665 m / s2) shall be 1 mH2O = 0.1kgf / cm2 = 9.8kPa
  7. Please contact us in case of the other special requirements and clearly  indicate them when placing an order.


 

Product selection

HM21F

Lightning Liquid Level Transducer

 

Guideline of Selection

 Lightning Liquid Level Transducer

 

Range

Measuring Range

 

0 ~ X mH2O or 0 ~ X KPa

 

 

 

Code

Structural form (maximum range of operating scale)

 

 

 

C1

Integrated: (0 ~ 200mH2O)

 

 

 

C2

Split: (0 ~ 10mH2O)

 

 

 

C3

Inserted: (0 ~ 4mH2O)

 

 

 

 

 

Code

Overall accuracy (linear + repeatability + lagging)

 

 

 

 

 

0

 ± 0.1% FS

 

 

 

 

 

1

 ± 0.4% FS

 

 

 

 

 

2

 ± 0.25% FS

 

 

 

 

 

 

 

Code

Signal Output (standard power supply of energization)

 

 

 

 

 

 

 

A1

4 ~ 20mA(12 ~ 36V DC)

 

 

 

 

 

 

 

V1

1 ~ 5V(12 ~ 36V DC)

 

 

 

 

 

 

 

V2

0 ~ 5V DC(12 ~ 36V DC)

 

 

 

 

 

 

 

 

 

Code 

Additional functions

 

 

 

 

 

 

 

 

 

F1

G 1 1 / 2 external thread (split and inserted)

 

 

 

 

 

 

 

 

 

F2

DN 20 flange (split and inserted)

 

 

 

 

 

 

 

 

 

F0

Special

 

 

 

 

 

 

 

 

 

E

Intrinsically safe explosion - proof type Ex ia II CT5

 

 

 

 

 

 

 

 

 

 

 

 

HM21F ( 0 ~ 10mH2O)

 —C 1

— 1

— A1

 

 

— E

 Lightning Liquid Level Transducer

Tips of Selection 

 The medium to be measured shall be compatible with the material contacting with the product. Meanwhile, it is needed to be indicated with density of the medium to be measured under the measuring status (except for water). Please indicate when placing an order in case of battery power supplying. The F1, F2, and F0 shown as the additional functions are only suitable for split–type liquid level transducer and inserted–type liquid level transducer. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier. The length of cable shall be L = X m + 1m. Please indicate for extension when placing an order. There are two kinds of cable material. The polyurethane is more flexible with good wear resistance, which may be selectively used. Under the condition without special indication, the PVC cables shall be supplied. The corresponding relationship of 1m water column under standard condition ( i.e. 4℃, g = 9.80665 m / s2) shall be 1 mH2O = 0.1kgf / cm2 = 9.8kPa Please contact us in case of the other special requirements and clearly indicate them when placing an order.

bottom-nav_01.png

主要產(chǎn)品:
HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |