Product catalog
- HM10 High - accuracy Pressure Sensor
- HM20 General - type Pressure Transducer Description
- HM22 High - accuracy Pressure Transducer
- HM23 Special Pressure Transducer for Air Conditioner, Refrigerating and Compressor
- HM23Y Special Pressure Transducer for Oilfield and Mining Well
- HM24 Economical Pressure Sensor and Transducer
- HM25 Industrial - type Pressure Transducer
- HM26 Ceramic Capacitor Pressure Transducer
- HM27 Vacuum / Absolute Pressure Transducer
- HM28 Sapphire Pressure Transducer
- HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer
- HM50 Anti - corrosive Pressure Transducer
- HM60 Anti - explosive Pressure Transducer
- HM70 Hygienic Flat - membrane Pressure Transducer
- HM80 High - temperature Pressure Transducer
- HM90 High - frequency Dynamic Pressure Transducer
- HM91 Micro Pressure Sensor and Transducer
Contact Us
南京宏沐科技有限公司
銷售部地址:南京市高鐵南站南廣場(chǎng)
電話:400-063-9658
手機(jī):18951963348同微信號(hào)
傳真:025-52150140
郵箱:njhongmu@hmsensor.com
HM60 Anti - explosive Pressure Transducer
Description
HM60 series of anti - explosive pressure transducer is specially designed for high – explosive dangerous site, which may provide stable and accurate measurement under an absolute pressure, gauge pressure, and differential pressure from -100KPa to 200MPa. It has welded the existing German HELM made multi – crystalline silicon film sensing element together with the enclosure using welding technology to accommodate the individualization of needs for the different users and it may keep all the features of the genuine HELM pressure sensing chip. It is designed with diversified built – in amplification circuit and may be provided with M 20 x 1.5 or G1 / 2 internal thread explosion – proof flexible tube connector.
Features of Product
☆ Intrinsically safe and explosion – isolating certification: Ex d II CT5, Ex d II CT6
☆ Measuring range:-100kPa ~ 0 ~ 200KPa … 5KPa… 200MPa
☆ Optional gauge pressure, absolute pressure, differential pressure
☆ Adoption of explosion – proof genuine HELM pressure sensing chip multi – crystalline silicon film chip, with stable and reliable performance and long service life
☆ Reverse pole and over – voltage protection of power supply
☆ Explosion – proof design, with safety and reliability
☆ Strong disturbance immunity, strong vibrant resistance, and excellent long – term stability
Application of Product
Details
HM60 series of anti - explosive pressure transducer features good performance, small dimensions, flexible design. It features very high ratio of performance to cost and long service life comparing with traditional explosion – proof transducer. It may widely be used for such fields as oilfield, mining well, chemical, electric power, boiler, and natural gas etc. HM60 – E type of pressure transducer is of intrinsically safe explosion – proof pressure transducer, with an explosion – proof marking of Ex ia II CT5, of which explosion – proof certificate of conformity number is CNEx07.0988. It features stable and reliable performance supporting with repetitive type of safety energy limiter or safety barrier. HM60 – D type of pressure transducer is explosion – isolating type of pressure transducer, with an explosion – proof marking of Ex d II CT6, of which explosion – proof certificate of conformity number is CNEx08.2405. HM60 – ED type of pressure transducer is explosion – isolating type of pressure transducer, with an explosion – proof marking of Ex d II CT5, Ex d II CT6, without safety barrier when installing and operating, with simple operation, safety, and reliability.
Technical Data | |||
Measuring range | -100kPa ~ 0 ~ 200KPa … 5KPa… 200MPa | ||
Overloading capacity | Two times of FS pressure (where over pressure for 100MPa is designed with 1.1 times of FS pressure | ||
Pressure type | Gauge pressure, absolute pressure, differential pressure | ||
Medium to be measured | The gas or liquid compatible with 316 stainless steel | ||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year | |
Zero point temperature drifting | Typical: ± 0.2% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |
Sensitivity temperature drifting | Typical: ± 0.2% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |
Operating temperature | -20 ~ +85 ℃ | ||
Compensating temperature | -20 ~ +60 ℃ | ||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | ||
Signal output | 4 ~ 20mA / 1 ~ 5V DC / 0 ~ 5V DC | ||
Load resistance | ≤ (U-12) / 0.02Ω | ||
Insulation resistance | ≥ 2000MΩ (100VDC for testing condition) | ||
Resolution | Infinite small (theoretical) 1 / 100000 (general) | ||
Response time | ≤1 ms | ||
Influence of vibration | Within mechanical vibration frequency 20Hz ~ 1000Hz, change of output is less than 0.1% FS | ||
Weight | Approx. 0.5kg |
Product selection
HM60 | Anti - explosive Pressure Transducer |
| Guideline of Selection | ||||||||||
| Code | Type of pressure | |||||||||||
| G | Gauge pressure ( may not be indicated) | |||||||||||
| A | Absolute pressure | |||||||||||
| D | Differential pressure | |||||||||||
|
| Range | Measuring Range | ||||||||||
|
| (0 ~ X MPa) measuring range | |||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | |||||||
|
|
|
|
| 1 | ± 0.4% FS | |||||||
|
|
|
|
| 2 | ± 0.25% FS | |||||||
|
|
|
|
| 3 | ± 0.1% FS | |||||||
|
|
|
|
|
|
| Code | Signal Output | |||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | |||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | |||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | |||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | |||||
|
|
|
|
|
|
|
|
| Code | Additional functions | |||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | |||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | |||
|
|
|
|
|
|
|
|
| F0 | Special | |||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | |||
|
|
|
|
|
|
|
|
| W2 | Hirschman socket type (IP65, DIN 43650) | |||
|
|
|
|
|
|
|
|
| W3 | Outline drawing (I) | |||
|
|
|
|
|
|
|
|
| W4 | Outline drawing (II) | |||
|
|
|
|
|
|
|
|
| W0 | Special | |||
|
|
|
|
|
|
|
|
| L1 | Pointer scale (0 ~ 100%) display | |||
|
|
|
|
|
|
|
|
| L2 | 3 1 / 2 LCD display | |||
|
|
|
|
|
|
|
|
| L3 | 3 1 / 2 LED display | |||
|
|
|
|
|
|
|
|
| P | Flushed membrane | |||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | |||
|
|
|
|
|
|
|
|
| D | Explosion - isolating type Ex ia II CT6 | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
HM60 |
| — 1 | — A1 | — F1 | — W3 -D Anti - explosive Pressure Transducer |
Tips of Selection
- The medium to be measured shall be compatible with the material contacting with the product.
- The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
- The code D, an additional functional code for selection and explosion-isolating Ex ia II CT6 must be preferably provided with explosion – proof flexible hose for the electrical power on the downstream of it.
- The options W1 and W4 is for general type of structural encapsulation, which is only used for HM60 – E intrinsically safe explosion – proof pressure transducer.
- HM60 – ED intrinsically safe explosion – isolating pressure transducer is unnecessarily provided with safety barrier when the system is operating.